Provide Valid D-PVM-OE-23 Dumps To Help You Prepare For Dell PowerMax and VMAX Family Solutions Operate 2023 Exam Dec 03, 2024 [Q118-Q136]

Share

Provide Valid D-PVM-OE-23 Dumps To Help You Prepare For Dell PowerMax and VMAX Family Solutions Operate 2023 Exam Dec 03, 2024

EMC D-PVM-OE-23 Dumps Questions [2024] Pass for D-PVM-OE-23 Exam

NEW QUESTION # 118
How many linked targets, per source, are allowed when using TimeFinder SnapVX?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 119
What are the SRDF group limits of a VMAX3 when connected to a VMAX?

  • A. 250 RDF groups per system250 RDF groups per RDF port32 RDF ports per engine.
  • B. 64 RDF groups per system64 RDF groups per RDF port connected to the VMAX32 RDF ports per engine.
  • C. 250 RDF groups per system64 RDF groups per RDF port connected to the VMAX32 RDF ports per engine.
  • D. 250 RDF groups per system250 RDF groups per RDF port16 RDF ports per engine.

Answer: C


NEW QUESTION # 120
Which type of emulation is used for thin devices provisioned to an eNAS Storage Group in VMAX3?

  • A. CELERRA_FBA
  • B. FBA
  • C. EMBEDDED_NAS_FBA
  • D. eNAS_FBA

Answer: A


NEW QUESTION # 121
What is the default copy mode for Open Replication pull operations?

  • A. NoCopy
  • B. Copy-on-Access
  • C. Background copy
  • D. Donor Update

Answer: C


NEW QUESTION # 122
Unisphere for VMAX was recently installed and the default HTTPS port was used.
What must be done in order to change the default port?

  • A. Update the SYMAPI server with the correct HTTPS port.
  • B. Overwrite the HTTPS port.
  • C. Default port must be retained.
  • D. Uninstall and re-install the application.

Answer: C


NEW QUESTION # 123
When using TimeFinder SnapVX technology, what is the maximum number of linked targets of a snapshot that can be created?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 124
Which service has to be manually started first when Unisphere services are down?

  • A. SMAS
  • B. SMASDB
  • C. SYMEVENT
  • D. SMI-S

Answer: A


NEW QUESTION # 125
An administrator is managing two PowerMax arrays that are located in two different data centers. The data centers are 50 km apart and are connected by a high bandwidth, low latency network link. The administrator wants to replicate data between the two arrays and achieve the lowest RTO.
When using SRDF, which mode meets this requirement?

  • A. Asynchronous
  • B. Synchronous
  • C. Adaptive Copy
  • D. Metro

Answer: D


NEW QUESTION # 126
Which EMC VMAX3 point-in-time replication technology allows snapshots to be created without requiring a target volume?

  • A. TimeFinder SnapVX
  • B. Open Replicator
  • C. ProtectPoint
  • D. SRDF/Asynchronous

Answer: A


NEW QUESTION # 127
You are attempting to install Unisphere for VMAX 8.0 on a server with the following configuration:
- Microsoft Windows Server 2008 32-bit
- Dual core processor
- 16 GB RAM
- 180 GB free space
The installation is unable to continue because a pre-requisite has not been met.
What is the likely cause of the error?

  • A. 24 GB of RAM is required.
  • B. 64-bit operating system is required.
  • C. Quad core processor is required.
  • D. 240 GB of free space is required.

Answer: B


NEW QUESTION # 128
At which level does Non-Disruptive Migration work?

  • A. Initiator Group
  • B. Disk Group
  • C. Storage Group
  • D. Port Group

Answer: C


NEW QUESTION # 129
At which level should the SLO be associated to have a device managed by FAST on a VMAX3?

  • A. Device Group
  • B. Masking View
  • C. Storage Group
  • D. Data Pool

Answer: B


NEW QUESTION # 130
An administrator has just migrated block data from a Unified VNX array to a new VMAX3 array. The administrator now wants to migrate the file data from the Unified VNX to the new array.
The VMAX3 is not configured with eNAS and the administrator wants to enable it.
What is required to enable eNAS?

  • A. eNAS must be installed at the factory
  • B. Contact Support and have them enable it through ESRS
  • C. Use SYMCLI to enable eNAS on the array
  • D. Obtain the eNAS binaries and install them

Answer: A


NEW QUESTION # 131
What is a primary FAST runtime task?

  • A. Monitor the front-end ports
  • B. Monitor SRDF performance
  • C. Monitor the workload on disk groups
  • D. Monitor the back-end ports

Answer: C


NEW QUESTION # 132
A storage administrator has expanded a Storage Group where TimeFinder SnapVX snapshots were already present.
If a Snapshot Restore operation is performed, what will be the state of the new volumes?

  • A. Read/Write
  • B. Not Ready
  • C. Not affected
  • D. Write Disabled

Answer: B


NEW QUESTION # 133
On a VMAX All Flash, what is the minimum user role required to setup thresholds to monitor array operations?

  • A. Auditor
  • B. StorageAdmin
  • C. StorageAdmin
  • D. PerfMonitor

Answer: D


NEW QUESTION # 134
What is the maximum number of bricks that can be configured on a PowerMax 8000 system bay?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 135
Which feature of VMAX3 and VMAX All Flash arrays extends storage tiering and Service Level management to other storage platforms and the cloud?

  • A. FAST.X
  • B. SRDF
  • C. FAST
  • D. eManagement

Answer: A


NEW QUESTION # 136
......

Achieve Success in Actual D-PVM-OE-23 Exam D-PVM-OE-23 Exam Dumps: https://surepass.free4dump.com/D-PVM-OE-23-real-dump.html